==== Solar -PhotoVoltaic- Power Plant[s] ==== //Notes from a session held at the Luminous Green Hands-On Workshop, 2nd of May 2007// * How to calculate the power requirements, size and cost for a photovoltaic system installation * see Marko Peljhan's pdf http://luminousgreen.org/articles/sizing-solar.pdf * see also on FoAM's libarynth: http://libarynth.org/photovoltaics ===== Size your photovoltaic system in 20 steps ===== ====== **1/ Calculate AC equipment loads in Watt hours per week** Example: Computer (500W)+ Projector (2000W) + Sensors AC-Loads: 500W x hrs/week (e.g.56) = 2 800W/wk + 13 200W/wk = 16 000Wh/wk **2/ Inverter Loss - Energy needs of the Invertor (12V) => multiply by 1,2** => 16000W/wk x1.2 = 19 200 W/wk **3/ Calculate Amps/h load per week: Divide Wh/Wk corrected by inverter input voltage (usually 12V)** Ω Law: (V.A=W) --> 19200W/Wk / 12V = 1600Amph/Wk **4/ Calculate DC equipment loads in Watt hours per week** / **5/ Divide DCWh/Wk by DC system voltage (12,24,48 or whatever it is) to get Amp hours per week load** / **6/ Get total Amp hours per week load by adding 3 + 5** 1600Ah/Wk + 0 **7/ Divide by 7 to get amp hours per day** 1600Amph/Wk /7days = 228,5Amph/day **8/ Days of storage needed** Multiply Amph/Day with the days of storage needed to get total system Amph storage needed. Besides the choice of machines, this determines the project cost. Hybrid systems are better than Solar only. Our example -> 5 days capacity: => 228,5Amph/day x 5 = 1140 A/h **9/ Take into account a battery discharge limit factor** Divide Total system Amp hours needed with the discharge limit of batteries (0.5 for 50%, it can be from 0.2 to 0.8, depending on the batteries used) Deep cycle batteries like the one we use (car battery) do not like to go below 50% Factor 0,5 compensation (in this case). => Capacity 1140Ah/0,5= 2280A/h If you make an installation work that is not up and running all the time, batteries go dead. **10/ Multiply the TOTAL System Amph Corrected with the winter multiplier** Reserve storage capacity, depends on temperature and hours of sun 26,7° -> 1,00 21,2° -> 1,04 15,6° -> 1,11 10,0° -> 1,19 4,4° -> 1,30 -6,7° -> 1,59 //Note: 1,11 = experience based “magic number” // => 2280Amph/day x 1,11 = 2530Amph **11/ Get number of batteries needed to be connected in parallel** Divide the total system (winter corrected) amperage needed, with the amp hours rating of your batteries. 2530Amph / 75Amph => 34 batteries (of 12V) **12/ Get number of batteries wired in series needed** System Voltage (12,24,48...) / Battery Voltage= number of batteries wired in series =1 **13/ Get total number of batteries needed** Multiply baterries parallel and batteries in series. =34 **14/Correct the TOTALAmph/Day needed for battery loss, factor 1.2** 228,5Amph/day x 1,2= 274,2 Amph/day **15/ Determine the Solar panel size** Calculate the total solar panel array amps needed for your system TOTAL Amph/Day Battery loss corrected / Average Sun Hours per day = 274,2 Amph/day / 15 (hours of sun/day) = 18,28Amph **16/ Get the total parallel number of modules needed** Divide your total solar array Amps with the Peak amps produced by each module. You calculate your Peak amps if you divide the module Wattage with the peak power point voltage (see the specs of your modules, PeakAmps/panel). Round off to the highest whole number. Our Kyocera panel: 2,33Amp => 18,28Amph/2,33Amp= 8 panels **17/ Determine the number of modules in each series string needed to supply necessary DC battery Voltage** DC Battery Voltage Number of Modules in each series string 48V --> 4 24V --> 2 12V --> 1 The higher Voltage the more efficient (Ω Law) -> you want to have lower Amperage. The higher the current, the higher heat and the more expensive the cables will be. Batteries put in parallel increase the Amperage; Heat will built up => Serial = better, although sometimes you need more amperage => combine sytems, put many serial banks in parallel f.i. **18/ Determine the total number of modules needed** Multiply the total number of modules if wired in parallel by the multiplier from the chart above according to battery voltage. 8 panels x 4 (12V) = 32 **19/ Get the MINIMUM Amp for the solar charger** Multiply the peak amps by module by the number of modules take Peak Amps per panel: 2,33Amps -> x 8modules = 18,64Amps Minimum **20/ Calculate your inverter power rating** Multiply your AC simultaneous loads and possible surges from electric motors and multiply by 1.2 for inverter loss to get total inverter power rating. 2500W continuous. Take into account that a stepper motor or kinetic solutions take a lot of energy for a short time. Therefore, add 1000W for the motor used in the installation in this example. => + 1000W = 3500W x 1,2= 4200 ---- **System set up hands on workshop** Components: Solar panel, Charger, Battery (simple car battery), Invertor ac-dc: (uses power, so for mini systems to avoid (or DC-DC Convertor)) Set up On the panel backside is the terminal, watch for blue (+) and brown (-) and connect to the charger Brown (+) Blue (-) INSTALL RULE OF THUMB --> 90° > Sun In function/Inclination/Inclinometer > 51° Lattitude Measure the power voltage Connect to the battery How it functions: light absorbed during the day, charging. At night particles go back, but charge has to be released. ---- {{tag>solar}}