Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revisionBoth sides next revision
michka:research:microbial_fuel_cells [2014-07-11 10:30] michkamichka:research:microbial_fuel_cells [2014-07-11 10:38] michka
Line 21: Line 21:
 ===One Container Design=== ===One Container Design===
  
-Wiring as electrode.+   Wiring as electrode.
  
 ==Results== ==Results==
  
-Voltage changes with oxygenation.+   * Peak voltage at 100mV, drops to 60, stable. 
 +   Voltage changes with oxygenation - + 10 mV.
  
 ===One Container in Crate Design=== ===One Container in Crate Design===
 +
 +   * Layed down the jar in a crate covered with a plastic bag and filled with water.
 +   * Five times bigger cathode, made of wiring, and then replaced by a flattened aluminium can.
  
 ==Why ?== ==Why ?==
  
-Augemented cathode surface area & reduced water layer width for oxygen access.+   Augemented cathode surface area & reduced water layer width for oxygen access
 + 
 +==Results== 
 + 
 +   * No improved voltage with bigger wiring cathode. 
 +   * Improved voltage (300 mV) with aluminium can cathode. 
 +   * When putting directly the multimeter cathode in water, we obtain 600 mV. 
 + 
 +==Conclusion== 
 + 
 +   * The geometry of the multimeter cathode may be better for voltage than the one made of wiring or aluminium can. However, surface area is necessary to obtain current.
  
 ===Crate Paper Design=== ===Crate Paper Design===
Line 46: Line 60:
  
    * Negative voltage when putting a rock on cathode to maintain it in water.    * Negative voltage when putting a rock on cathode to maintain it in water.
 +   * No improved voltage by the new flat design.
 +   * Still no current measurable, probably very low.
 +
 +==Conclusion==
 +
 +   * Is paper a good PEM ?
  
 ===Two Containers Design=== ===Two Containers Design===
Line 57: Line 77:
      * If water is not clean, voltage increases up to 100 mV.      * If water is not clean, voltage increases up to 100 mV.
    * Two multimeter electrodes in the mud: 10-80 mV depending on location.    * Two multimeter electrodes in the mud: 10-80 mV depending on location.
 +
 +===Overall Conclusion===
 +
 +   * Maybe it needs a longer period to get started - eating up all the oxygen around the anode.
 +   * Maybe our PEMs are not good.
  
 ====Design Improvements Ideas==== ====Design Improvements Ideas====
  • michka/research/microbial_fuel_cells.txt
  • Last modified: 2018-04-26 12:44
  • by michka